Validates endurance and stability of low-power CGM batteries.
Supports long-term micro-current cycling with ±0.01% F.S. accuracy to simulate real-world CGM operation.
Precision Micro-Current Testing: 0.2μA~100mA range replicates monitoring and Bluetooth power consumption.
Extended Cycle Testing: up to 65,500 cycles evaluate capacity fade and lifespan.
Compliant Data Export: full data export and cloud storage meet medical standards.
Voltage & Current Accuracy: ±0.01% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Minimum Pulse Width: 500ms
Off-Line Test: 1GB
Voltage&Current Accuracy: ±0.01% F.S.
Recording Frequency: 1000Hz
Current Response Time: ≤20μs
CV Testing
Type-C Power Port
6-Range Current Measurement
Provides SMBus communication, multi-range testing, and high-speed sampling to analyze electrochemical behavior and ensure medical safety compliance.
SMBus communication: real-time BMS monitoring for status and lifespan prediction.
DCIR and CV testing: precisely measures internal resistance and electrochemical activity.
Safety validation: overcharge, short-circuit, and over-discharge tests per IEC 60601-1/UL 2054.
Voltage & Current Accuracy: ±0.02% F.S.
Voltage Stability: ±0.01% F.S.
Current Stability: ±0.015% F.S.
Sampling Frequency: 100Hz
Resolution AD: 16bit
Current Response Time: ≤1ms
Combines charge/discharge testing with temperature simulation to validate CGM battery performance across body temperature and extreme environments.
Body temperature simulation: tests battery performance from 25°C to 60°C under real-wear CGM conditions.
Extreme environment validation: operates from -40°C to 150°C for reliability verification.
Accelerated life testing: temperature cycling reveals aging effects for durable designs.
Voltage & Current Accuracy: ±0.05% F.S.
Sampling Time: 100ms
Number of Channels: 16CH
Temperature Range & Deviation: 32℉~140℉±3.6℉(15℃~60℃±2.0℃)
Heating Efficiency: 77℉~140℉≤50min
(25℃~60℃≤50min)
Cooling Efficiency: 77℉~59℉≤60min
(25℃~15℃≤60min)
Voltage & Current Accuracy: ±0.01% F.S.
Recording Frequency: 100Hz
Number of Channels: 160CH
Temperature Range & Deviation: 32℉~140℉±3.6℉(0℃~60℃±2.0℃)
Heating Efficiency: 77℉~140℉≤30min
(25℃~60℃≤30min)
Cooling Efficiency: 77℉~32℉≤50min
(25℃~0 ℃≤50min)
Current & Voltage Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Current Response Time: ≤1ms
Temperature Range: 32°F~140°F (0℃~60℃)
Heating Time: 77°F→140°F≤30min
(25℃→60℃≤30min)
Cooling Time: 77°F→32°F≤50min
(25℃→0℃≤50min)
Current & Voltage Accuracy: ±0.05% F.S.
Data Logging Frequency: 10Hz
Temperature Range & Deviation: -94°F~302°F ±3.6°F(-70℃~150℃±2℃)
Temperature Fluctuation: ≤0.9°F(≤0.5℃)
Heating Time: 68°F→302°F≤60min
(20℃→150℃≤60min)
Cooling Time: 68°F→-94°F≤75min
(20℃→-70℃≤75min)
September 09, 2024
June 26, 2025
April 16, 2024
August 26, 2025