There are water droplets inside or on the surface of the incubator
There are water droplets inside or on the surface of the incubator
HARDWARE

There are water droplets inside or on the surface of the incubator

It may be due to the heating element of the chamber not functioning properly, requiring inspection or replacement.
Loss of temperature control in the incubator
Loss of temperature control in the incubator
HARDWARE

Loss of temperature control in the incubator

There are upper limit setting temperature, lower limit setting temperature and independent over-temperature protection on the temperature chamber controller.
The humidifier of the incubator does not work, resulting in the temperature insi
The humidifier of the incubator does not work, resulting in the temperature insi
HARDWARE

The humidifier of the incubator does not work, resulting in the temperature insi

1. Need to confirm whether the humidifier heater is working properly. 2. Need to confirm whether the humidification system is short of water, such as water shortage need to promptly replenish the equipment required water quality (deionised water or pure water) water.
The temperature chamber cooling speed is slow or can not fall to the set tempera
The temperature chamber cooling speed is slow or can not fall to the set tempera
HARDWARE

The temperature chamber cooling speed is slow or can not fall to the set tempera

It is necessary to confirm whether the refrigeration unit is electrified for normal operation, and check whether the compressor can operate normally.
The temperature of the temperature chamber rises slowly or fails to rise to the
The temperature of the temperature chamber rises slowly or fails to rise to the
HARDWARE

The temperature of the temperature chamber rises slowly or fails to rise to the

Need to confirm whether the electric heating tube is energised normally, to determine whether the electric heating tube is burnt or damaged by the damage of the electrical components.
Temperature chamber communication is not working
Temperature chamber communication is not working
HARDWARE

Temperature chamber communication is not working

1. Check the wiring sequence. 2. Check the environment configuration. 3. Check the version information.
Introduction to Environmental Test Chamber
Introduction to Environmental Test Chamber
HARDWARE

Introduction to Environmental Test Chamber

What is a humidified temperature chamber? Humidification type temperature chamber is a temperature chamber that controls humidity within a certain range. In the equipment code, H stands for humidification model.
Temperature deviation in the temperature chamber (temperature instability)
Temperature deviation in the temperature chamber (temperature instability)
HARDWARE

Temperature deviation in the temperature chamber (temperature instability)

Clean the temperature chamber cooling fan of dust. Remove the bottom baffle of the unit and clean the condenser dust. Needs to be cleaned every three months.
How to resume testing after replacing the computer and reinstalling the software
How to resume testing after replacing the computer and reinstalling the software
SYSTEM

How to resume testing after replacing the computer and reinstalling the software

After replacing the computer, if you need to resume testing, you should copy the client and server files installed on the original computer to the new computer, and ensure the installation discs are consistent.
How to handle large test data volume
How to handle large test data volume
SYSTEM

How to handle large test data volume

The large data volume is due to the small channel sampling time.
Software upgrade precautions
Software upgrade precautions
SYSTEM

Software upgrade precautions

If you need to upgrade the software, first ensure that the previous test data and steps have been saved because after the program upgrade, data cannot be resumed.
NEWARE BTS Connection Failure Troubleshooting Guide
NEWARE BTS Connection Failure Troubleshooting Guide
CONNECTION

NEWARE BTS Connection Failure Troubleshooting GuideHOT

Troubleshooting steps for NEWARE BTS connection failure, including hardware check, IP configuration, firewall shutdown and service startup.
Precautions for connecting new and old equipment
Precautions for connecting new and old equipment
CONNECTION

Precautions for connecting new and old equipment

Firstly, please confirm that the serial number of the newly purchased host computer or the auxiliary channel does not conflict with the serial numbers of existing old equipment.
Data fluctuations
Data fluctuations
DATAS

Data fluctuations

If there are random data anomalies, first check if the fixture is causing the issue.
Computer antivirus caused data to be unable to open
Computer antivirus caused data to be unable to open
CONNECTION

Computer antivirus caused data to be unable to open

Solution 1: Recover data from the antivirus software quarantine area.Using 360 antivirus software as an example: Go to the Security Operations Center, then access the recoverable area.
Solutions for BTSDA Data Opening Failure
Solutions for BTSDA Data Opening Failure
SOFTWARE

Solutions for BTSDA Data Opening Failure

Two fixes for NEWARE BTSDA data opening failure, use BTSDAEx and install the C++ patch from the software installation package.

Hot Questions

View all FAQs

Still can't find your answer?

Our application engineers are ready to help with technical issues, calibration requests, and custom testing solutions.

NEWARE and Cookies
We use cookies to personalize and improve your experience with our website. By continuing to browse the site you are agreeing to our use of cookies.