Features
Tech Specs
Single-channel voltage range: 100V to 1500V, current range: 200A to 1600A (customizable). Supports parallel operation of up to 4 channels (pulse/simulation testing unavailable in parallel mode), enabling seamless testing for energy storage Packs, ultra-high-voltage battery clusters, and high-voltage DC source simulation testing (PCS testing).
AC/DC and DC/DC dual-stage high-frequency isolated modular architecture enhances system scalability and flexibility, ensuring efficient production and maintenance.
Multi-protocol communication interfaces: Supports TCP/IP Ethernet, CAN FD/CAN/RS485, and mainstream BMS systems, enabling real-time data interaction and remote monitoring.
Peripheral synergy: Integrates with water chillers, high/low-temperature environmental chambers, vibration testers, and other equipment to build a unified testing platform. Simulates complex operating conditions (e.g., high/low-temperature charge/discharge, vibration-based performance validation).
Precision data acquisition & logging: 24-bit high-resolution voltage/current sampling with a minimum recording interval of 10ms (100ms for auxiliary channels). Centralized MySQL database management ensures traceability across millions of test data entries.
Intelligent analysis & visualization: Supports Excel/TXT data export and features built-in DCIR (Direct Current Internal Resistance) testing functionality for rapid report generation, boosting R&D efficiency.
Equipment name | 1500V Ultra-High Voltage Battery Cluster Solution |
---|---|
Model | CE-6002-1500V200A |
Voltage | |
Output range | Charge:0V~1500V
Discharge :100V~1500V |
Min discharge voltage | 100V |
Accuracy | ±0.02% of F.S. |
Resolution | 24bit |
Current | |
Output range | 1A~200A |
Accuracy (independent range) | 0.02% of F.S. |
CV cut-off current | 0.05% of F.S.(Each independent range) |
Resolution | 24bit |
Power | |
Single channel output power | 300KW |
Whole machine output power | 600KW |
Time | |
Current response time | ≤10ms |
Current conversion time | ≤20ms |
Voltage & Current Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Energy Efficiency: >65%
Off-Line Test: 1GB
Voltage & Current Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Energy Efficiency: >65%
Off-Line Test: 1GB
Voltage & Current Accuracy: ±0.01% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Minimum Pulse Width: 500ms
Off-Line Test: 1GB
Current & Voltage Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Current Response Time: ≤1ms
Temperature Range: 32°F~140°F (0℃~60℃)
Heating Time: 77°F→140°F≤30min
(25℃→60℃≤30min)
Cooling Time: 77°F→32°F≤50min
(25℃→0℃≤50min)
Current & Voltage Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Current Response Time: ≤1ms
Temperature Range: 32°F~140°F (0℃~60℃)
Heating Time: 77°F→140°F≤30min
(25℃→60℃≤30min)
Cooling Time: 77°F→32°F≤50min
(25℃→0℃≤50min)
Voltage & Current Accuracy: ±0.01% F.S.
Recording Frequency: 100Hz
Number of Channels: 160CH
Temperature Range & Deviation: 32℉~140℉±3.6℉(0℃~60℃±2.0℃)
Heating Efficiency: 77℉~140℉≤30min
(25℃~60℃≤30min)
Cooling Efficiency: 77℉~32℉≤50min
(25℃~0 ℃≤50min)
Voltage & Current Accuracy: ±0.05% F.S.
Sampling Time: 100ms
Number of Channels: 16CH
Temperature Range & Deviation: 32℉~140℉±3.6℉(15℃~60℃±2.0℃)
Heating Efficiency: 77℉~140℉≤50min
(25℃~60℃≤50min)
Cooling Efficiency: 77℉~59℉≤60min
(25℃~15℃≤60min)
Voltage&Current Accuracy: ±0.01% F.S.
Recording Frequency: 1000Hz
Current Response Time: ≤20μs
CV Testing
Type-C Power Port
6-Range Current Measurement