CT-8002Q-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002Q-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002Q-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002Q-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002Q-5V100mA-124 NEWARE Battery Testing Solutions

CT-8002Q-5V100mA-124

CT-8000 Battery Testing System

NEWARE battery tester CT-8002Q-5V100mA is suitable for testing button batteries and supercapacitors. 4 ranges from 0.2 μA to 100 mA,2 channels.Including HPPC and GITT

● Voltage&Current Accuracy:±0.01% F.S.

● Recording Frequency:100Hz

● Current Response Time:≤1ms

● Minimum Pulse Width:500ms

● Off-Line Test:1GB/CH

● Cycle Life, GITT Test, DCIR Test, dQ/dV Curve

For Coin Cells, Super Capacitors, Three-Electrode Systems Testing and etc.

* This product model has been updated. For details, please refer to Battery Test Equipment, or consult a sales expert.

Read More
CE-8008-5V200A NEWARE Battery Testing Solutions
CE-8008-5V200A NEWARE Battery Testing Solutions
CE-8008-5V200A NEWARE Battery Testing Solutions
CE-8008-5V200A NEWARE Battery Testing Solutions

CE-8008-5V200A

CT/CE-8000 Battery Testing System

NEWARE 8008-5V200A battery tester for battery test, Electric vehicle battery, super capacitor, flow battery performs DOD,SOC,HPPC, tests, and data storage for test data.

● Voltage&Current Accuracy:±0.05% F.S.

● Recording Frequency:100Hz

● Working Condition Simulation:1,000,000 Rows

● Current Response Time:≤5ms

● Minimum Pulse Width:500ms

● Feedback Efficiency (Min) :65%

Work simulation for power safety. The product adopts modular design with each unit 8 channels which can be independently data acquisition and independently programmed to edit the maximum number of lines to support 254 lines.

* This product model has been updated. For details, please refer to Battery Test Equipment, or consult a sales expert.

Read More
CT-8002S-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002S-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002S-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002S-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002S-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002S-5V100mA-124 NEWARE Battery Testing Solutions
CT-8002S-5V100mA-124 NEWARE Battery Testing Solutions

CT-8002S-5V100mA-124

Portable Battery Testing System

Portable Battery Tester with CV and EIS testing, featuring high precision, fast response, and easy portability. Ideal for lab research and on-site battery testing.
  • Voltage & Current Accuracy±0.01% F.S.

  • Recording Frequency1000Hz

  • Current Response Time≤20μs 

  • CV Testing 

  • Type-C Power Port 

  • 6-Range Current Measurement

Portable battery testing system for battery materials research with in-situ testing support. 

· CV Testing 

· Current response time ≤20μs 

· Seamless Current Switching 

· Type-C Power Port 

· 6-Range Current Measurement

Read More
CT-8002S-5V100mA-EIS NEWARE Battery Testing Solutions
CT-8002S-5V100mA-EIS NEWARE Battery Testing Solutions
CT-8002S-5V100mA-EIS NEWARE Battery Testing Solutions
CT-8002S-5V100mA-EIS NEWARE Battery Testing Solutions
CT-8002S-5V100mA-EIS NEWARE Battery Testing Solutions
CT-8002S-5V100mA-EIS NEWARE Battery Testing Solutions
CT-8002S-5V100mA-EIS NEWARE Battery Testing Solutions
CT-8002S-5V100mA-EIS NEWARE Battery Testing Solutions

CT-8002S-5V100mA-EIS

CT-8000 Battery Testing System

Portable battery test system features high precision, fast response, rapid sampling, and multiple current ranges. In addition to conventional charge and discharge functions, it integrates both CV and EIS testing. Compact and lightweight, it can be conveniently used with other instruments for in-situ testing, making it highly suitable for battery research and development institutions.
  • Voltage & Current Accuracy: ±0.01% F.S.

  • Recording Frequency: 1000Hz

  • Current Response Time: ≤20μs 

  • CV & EIS Testing 

  • Type-C Power Port 

  • 6-Range Current Measurement

Powerful and ultra-high-precision portable battery testing system, meticulously engineered for battery R&D. 

· 0.01% F.S. voltage & current accuracy 

· 1 ms sampling interval 

· Integrated CV & EIS Testing 

· Microsecond-level current response time 

· No switching delay between charge and discharge

Read More

Powerful programmability. Meet diverse testing needs.

The software is fully functional, covering a variety of work-step settings, recording, and data storage to meet a wide range of testing needs.

DBC Configuration
  CC & CV charge/discharge test
500ms pulse width
Segmented recording
DBC Configuration
CC & CV charge/discharge test
500ms pulse width
Segmented recording
Support import/edit/export of DBC files. Different battery pack protocols can be communicated by simply modifying the code of the DBC protocol file without upgrading the program.
CC charging or discharging until the voltage reaches the specified value, and then seamlessly switching to CV mode for battery compensation which is smooth without any spikes.
Testing the performance of the battery under fast changes in current/power.
Allow to set up to 3 segment recording conditions per step, including voltage, current and time.

Electrochemical Instruments

We offer powerful battery test equipments, environmental test chambers to provide comprehensive testing support for battery testing.

CT-8002S-5V100mA-CV-thumb

Battery Test Equipment-NEWARE

CT-8002S-5V100mA-CV

Portable Battery Testing System

  • Voltage & Current Accuracy±0.01% F.S.

  • Recording Frequency1000Hz

  • Current Response Time≤20μs 

  • CV Testing 

  • Type-C Power Port 

  • 6-Range Current Measurement

CE-6004-Pro-5V600A-thumb

Battery Test Equipment-NEWARE

CE-6000-Pro Cell Testing System

CE-6000-Pro Power Cell Testing System

  • Voltage & Current Accuracy: ±0.02% F.S.

  • High-Frequency Sampling: 200Hz 

  • Current Conversion Time: ≤2ms

  • Current Response Time: ≤1ms

  • Minimum Pulse Width: 10ms

  • Feedback Efficiency (Max): 75%

CE-4008Q-5V30A-thumb

Battery Test Equipment-NEWARE

CE-4008Q-5V30A

CE-4000 Battery Testing System

  • Voltage & Current Accuracy±0.05% F.S.

  • Recording Frequency10Hz

  • Sampling Time100ms

  • Current Response Time≤1ms

  • Energy Efficiency>65%

  • Off-Line Test1GB

CE-4008Q-5V15A-thumb

Battery Test Equipment-NEWARE

CE-4008Q-5V15A

CE-4000 Battery Testing System

  • Voltage & Current Accuracy±0.05% F.S.

  • Recording Frequency10Hz

  • Sampling Time100ms

  • Current Response Time≤1ms

  • Energy Efficiency>65%

  • Off-Line Test1GB

NEWARE-Battery Tester-CT-4008Q-5V100mA-124

Battery Test Equipment-NEWARE

CT-4008Q-5V100mA-124

CT-4000 Battery Testing System

  • Voltage & Current Accuracy: ±0.01% F.S.

  • Recording Frequency10Hz

  • Sampling Time100ms

  • Current Response Time≤1ms

  • Minimum Pulse Width500ms

  • Off-Line Test1GB

WGDW-100L-70C-380V-5U-thumb

NEWARE-Environmental Test Chamber

WGDW-100L-70C-380V-5U

High and Low Temperature All-in-One Testing System

  • Volume: 100L

  • Space for Test System: 5U

  • Temperature Fluctuation: ≤0.9℉ (0.5℃) 

  • Temperature Deviation: ±3.6℉ (±2℃)

  • Heating Time: 68°F ~ 302°F≤60min 

    (20℃ ~ 150℃≤60min) 

  • Cooling Time: 68°F ~ -94°F≤75min

    (20℃ ~ -70℃≤75min) 

Contact Us

Your comments are important to us, and we will address them as quickly as possible.
Name
Country
City Name
Company Name
Phone Number
Email Address *
Products
Model
Detailed Request
NEWARE and Cookies
We use cookies to personalize and improve your experience with our website. By continuing to browse the site you are agreeing to our use of cookies.