Features
Tech Specs
Resources
The CE-5008Q-20V30A features a dual-closed-loop structure of constant current and constant voltage sources. It offers high-precision voltage and current testing, rapid response, and support for various testing modes, including constant current (CC), constant voltage (CV), CC-CV, and pulse charge/discharge. This makes it suitable for evaluating performance parameters of various batteries used in laptops, drones, and power tools, providing a comprehensive battery testing solution.
The system integrates a computer into the charge/discharge equipment rack, enabling standalone operation without an external computer. This design significantly saves laboratory space and reduces external wiring, lowering the risk of wiring failures and enhancing test reliability. It also supports remote monitoring and operation, enhancing the system's flexibility and convenience.
With 4 current ranges and rapid response, it captures battery performance details for reliable health assessment.
Covering 0.03A, 0.3A, 3A, and 30A, ±0.02% of F.S. accuracy, from micro - pulse discharge to 30A load testing, accurately captures battery degradation mechanisms.
≤30ms current response time to capture dynamic changes during charge/discharge, replicating real - world transient conditions.
8 channels sampled synchronously at 100Hz (Δt=0.01s/ΔI=30mA/ΔU=20mV) to detect micro-short-circuit internal resistance changes.
Four - wire measurement eliminates lead resistance errors.
Nested loops up to 4 layers deep to simulate complex real-world conditions, such as fast-charging followed by daily use or different load scenarios.
SMBus/I²C protocol parsing and custom DBC configuration read battery state data. It supports intelligent battery dynamic management and testing, synchronously decoding over 20 parameters including SOC/SOH/temperature. During testing, DBC files help identify issues by parsing messages and locating abnormal signals.
Equipment name | CE-5000 Battery Testing System |
---|---|
Model | CE-5008Q-20V30A-SMB-DS |
Input power | 7000W |
Resolution | AD: 16bit; DA: 16bit |
Voltage | |
Output range | 2.5V~20V |
Min discharge voltage | 2.5V |
Accuracy | ± 0.02% of F.S. |
Stability | 0.02% of F.S. |
Current | |
Output range | Range1: 0.03A; Range2: 0.3A; Range3: 3A; Range4: 30A |
Accuracy | ± 0.02% of F.S. |
Minimum output current | 3mA |
Stability | 0.02% of F.S. |
Power | |
Single channel output power | 600W |
Stability | 0.05% of F.S. |
Time and data record | |
Current response time | ≤30ms |
Working step time | 1~65535 min/step Time format-00:00:00.000(h, m, s, ms) |
Frequency | 100Hz |
Data record | Time Δt: (0.01s~300s) Voltage ΔU: (20mV~20V) Current ΔI: (30mA~30A) |
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Energy Efficiency:>65%
● Off-Line Test: 1GB
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:10Hz
● Sampling Time:100ms
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test: 1GB
● Voltage&Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Current Response Time:≤1ms
● Minimum Pulse Width:500ms
● Off-Line Test:1GB/CH
● Cycle Life, GITT Test, DCIR Test, dQ/dV Curve
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:100Hz
● Temperature Fluctuation:≤1.8℉(1℃)
● Temperature Range & Deviation:-40℉ ~ 302℉±3.6℉(-40℃ ~ 150℃±2.0℃)
● Heating Efficiency:68℉ ~ 302℉ ≤60min(20℃ ~ 150℃)
● Cooling Efficiency:68℉ ~ -40℉≤60min(20℃~-40℃)
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:100Hz
● Number of Channels:80CH
● Temperature Range & Deviation:50℉ ~ 185℉±3.6℉(10℃ ~ 85℃±2.0℃)
● Heating Efficiency:77℉ ~ 185℉ ≤40min(25℃ ~ 85℃)
● Cooling Efficiency:77℉ ~ 50℉≤40min(25℃~10 ℃)
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Number of Channels:160CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(0℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉ ≤30min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 32℉≤50min(25℃~0 ℃)
● Voltage & Current Accuracy:±0.05% F.S.
● Sampling Time:100ms
● Number of Channels:16CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(15℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉≤50min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 59℉≤60min(25℃~15 ℃)