Features

Tech Specs

High-speed communication & multi-channel acquisition 

Supports CAN FD 2Mbps high-speed transmission and RS485 long-distance communication, with 4 fully isolated channels for simultaneous battery module data acquisition. Precisely monitors critical parameters including voltage, temperature, and current, meeting the demands of high-frequency, high-precision monitoring in new energy vehicles, energy storage systems, and similar applications. 


Intelligent protocol compatibility 

Built-in CANFDNET-200U protocol stack, compatible with mainstream software such as ZLG CANPRO. Features multi-TCP Server connections (up to 4 paths), customizable port configurations, IP binding, and seamless integration with BMS, thermal chamber monitoring systems, and other devices. 


Ultra-low latency & lossless data capture 

Achieves 8,000 frames/s CANFD transmit/receive capability per channel (total), combined with 16KB network cache + 200 CANFD message buffer. Ensures <20ms transmission latency for complete data integrity under extreme conditions, ideal for high-frequency pulse signals or burst data scenarios. 


Robust industrial design 

1.5kV electromagnetic isolation for network ports and signal paths. Operates reliably in -20°C to 50°C environments. Simplifies deployment with static IP configuration and web-based management interface, ensuring long-term stability in industrial settings with strong interference resistance. 


Future-proof flexibility 

Supports dual-mode switching (CANFD/CAN), configurable RS485 baud rates (9.6K–115.2Kbps), and independent arbitration field/data field speed adjustments (up to 5M/2M). Includes software/hardware upgrade interfaces to adapt to future battery technology advancements.

Technical Specifications

Equipment name Power Battery DAQ Box
Channel Count 4 channels
Power Consumption 15W
Serial Interface RS485
CAN FD Bit Rates 125 K; 250 K; 500 K; 1 M; 2 M; 3 M; 4 M; 5 M bps
CAN FD Throughput 8,000 frames/sec per channel
Storage Temperature -20°C to 50°C
Dimensions 1U (19") 484×149×44 mm
Weight Approximately 2.2 kg

Electrochemical Instruments

We offer powerful battery test equipments, environmental test chambers to provide comprehensive testing support for battery testing.

CT-8002S-5V100mA-CV-thumb

Battery Test Equipment-NEWARE

CT-8002S-5V100mA-CV

Portable Battery Testing System

  • Voltage&Current Accuracy±0.01% F.S.

  • Recording Frequency1000Hz

  • Current Response Time≤20μs 

  • CV Testing 

  • Type-C Power Port 

  • 6-Range Current Measurement

CE-4008Q-5V30A-thumb

Battery Test Equipment-NEWARE

CE-4008Q-5V30A

CE-4000 Battery Testing System

  • Voltage & Current Accuracy±0.05% F.S.

  • Recording Frequency10Hz

  • Sampling Time100ms

  • Current Response Time≤1ms

  • Energy Efficiency>65%

  • Off-Line Test1GB

CE-4008Q-5V15A-thumb

Battery Test Equipment-NEWARE

CE-4008Q-5V15A

CE-4000 Battery Testing System

  • Voltage & Current Accuracy±0.05% F.S.

  • Recording Frequency10Hz

  • Sampling Time100ms

  • Current Response Time≤1ms

  • Energy Efficiency>65%

  • Off-Line Test1GB

NEWARE-Battery Tester-CT-4008Q-5V100mA-124

Battery Test Equipment-NEWARE

CT-4008Q-5V100mA-124

CT-4000 Battery Testing System

  • Voltage & Current Accuracy: ±0.01% F.S.

  • Recording Frequency10Hz

  • Sampling Time100ms

  • Current Response Time≤1ms

  • Minimum Pulse Width500ms

  • Off-Line Test1GB

NEWARE-Battery Tester-Power Cell All-in-One-WGDW-380L-2-40BFC-5V600A8CH

NEWARE-Environmental Test Chamber

WGDW-380L-2-40BFC-5V600A8CH

Power Cell All-in-One Testing System

  • Current & Voltage Accuracy: ±0.05% F.S.

  • Recording Frequency: 10Hz 

  • Current Response Time: ≤1ms 

  • Temperature Range: 32°F~140°F (0℃~60℃) 

  • Heating Time: 77°F→140°F≤30min

    (25℃→60℃≤30min) 

  • Cooling Time: 77°F→32°F≤50min

    (25℃→0℃≤50min)

NEWARE-Battery Tester-3C All-in-One Testing System-WGDW-380L-2-40BFC-5V600A8CH

NEWARE-Environmental Test Chamber

WHW-500L-5V6A80CH-380V

3C All-in-One Testing System

  • Current & Voltage Accuracy: ±0.05% F.S.

  • Recording Frequency: 10Hz 

  • Current Response Time: ≤1ms 

  • Temperature Range: 32°F~140°F (0℃~60℃) 

  • Heating Time: 77°F→140°F≤30min

    (25℃→60℃≤30min) 

  • Cooling Time: 77°F→32°F≤50min

    (25℃→0℃≤50min)

NEWARE-Battery Tester-All-in-One Testing System-WIHW-200L-160CH-B

NEWARE-Environmental Test Chamber

WHW-200L-160CH-B

Coin Cell All-in-One Testing System

  • Voltage & Current Accuracy: ±0.01%  F.S.

  • Recording Frequency: 100Hz

  • Number of Channels: 160CH

  • Temperature Range & Deviation: 32℉~140℉±3.6℉(0℃~60℃±2.0℃)

  • Heating Efficiency: 77℉~140℉≤30min

    (25℃~60℃≤30min)

  • Cooling Efficiency: 77℉~32℉≤50min

    (25℃~0 ℃≤50min)

NEWARE-Battery Tester- Mini All In One Testing System-WHW-25L-L-16CH

NEWARE-Environmental Test Chamber

WHW-25L-16CH

Mini All-in-One Testing System

  • Voltage & Current Accuracy: ±0.05% F.S.

  • Sampling Time: 100ms

  • Number of Channels: 16CH

  • Temperature Range & Deviation: 32℉~140℉±3.6℉(15℃~60℃±2.0℃)

  • Heating Efficiency: 77℉~140℉≤50min

    (25℃~60℃≤50min)

  • Cooling Efficiency: 77℉~59℉≤60min

    (25℃~15℃≤60min)

NEWARE and Cookies
We use cookies to personalize and improve your experience with our website. By continuing to browse the site you are agreeing to our use of cookies.