Features
Tech Specs
Supports CAN FD 2Mbps high-speed transmission and RS485 long-distance communication, with 4 fully isolated channels for simultaneous battery module data acquisition. Precisely monitors critical parameters including voltage, temperature, and current, meeting the demands of high-frequency, high-precision monitoring in new energy vehicles, energy storage systems, and similar applications.
Built-in CANFDNET-200U protocol stack, compatible with mainstream software such as ZLG CANPRO. Features multi-TCP Server connections (up to 4 paths), customizable port configurations, IP binding, and seamless integration with BMS, thermal chamber monitoring systems, and other devices.
Achieves 8,000 frames/s CANFD transmit/receive capability per channel (total), combined with 16KB network cache + 200 CANFD message buffer. Ensures <20ms transmission latency for complete data integrity under extreme conditions, ideal for high-frequency pulse signals or burst data scenarios.
1.5kV electromagnetic isolation for network ports and signal paths. Operates reliably in -20°C to 50°C environments. Simplifies deployment with static IP configuration and web-based management interface, ensuring long-term stability in industrial settings with strong interference resistance.
Supports dual-mode switching (CANFD/CAN), configurable RS485 baud rates (9.6K–115.2Kbps), and independent arbitration field/data field speed adjustments (up to 5M/2M). Includes software/hardware upgrade interfaces to adapt to future battery technology advancements.
Equipment name | Power Battery DAQ Box |
---|---|
Channel Count | 4 channels |
Power Consumption | 15W |
Serial Interface | RS485 |
CAN FD Bit Rates | 125 K; 250 K; 500 K; 1 M; 2 M; 3 M; 4 M; 5 M bps |
CAN FD Throughput | 8,000 frames/sec per channel |
Storage Temperature | -20°C to 50°C |
Dimensions | 1U (19") 484×149×44 mm |
Weight | Approximately 2.2 kg |
Voltage&Current Accuracy: ±0.01% F.S.
Recording Frequency: 1000Hz
Current Response Time: ≤20μs
CV Testing
Type-C Power Port
6-Range Current Measurement
Voltage & Current Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Energy Efficiency: >65%
Off-Line Test: 1GB
Voltage & Current Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Energy Efficiency: >65%
Off-Line Test: 1GB
Voltage & Current Accuracy: ±0.01% F.S.
Recording Frequency: 10Hz
Sampling Time: 100ms
Current Response Time: ≤1ms
Minimum Pulse Width: 500ms
Off-Line Test: 1GB
Current & Voltage Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Current Response Time: ≤1ms
Temperature Range: 32°F~140°F (0℃~60℃)
Heating Time: 77°F→140°F≤30min
(25℃→60℃≤30min)
Cooling Time: 77°F→32°F≤50min
(25℃→0℃≤50min)
Current & Voltage Accuracy: ±0.05% F.S.
Recording Frequency: 10Hz
Current Response Time: ≤1ms
Temperature Range: 32°F~140°F (0℃~60℃)
Heating Time: 77°F→140°F≤30min
(25℃→60℃≤30min)
Cooling Time: 77°F→32°F≤50min
(25℃→0℃≤50min)
Voltage & Current Accuracy: ±0.01% F.S.
Recording Frequency: 100Hz
Number of Channels: 160CH
Temperature Range & Deviation: 32℉~140℉±3.6℉(0℃~60℃±2.0℃)
Heating Efficiency: 77℉~140℉≤30min
(25℃~60℃≤30min)
Cooling Efficiency: 77℉~32℉≤50min
(25℃~0 ℃≤50min)
Voltage & Current Accuracy: ±0.05% F.S.
Sampling Time: 100ms
Number of Channels: 16CH
Temperature Range & Deviation: 32℉~140℉±3.6℉(15℃~60℃±2.0℃)
Heating Efficiency: 77℉~140℉≤50min
(25℃~60℃≤50min)
Cooling Efficiency: 77℉~59℉≤60min
(25℃~15℃≤60min)