High sampling accuracy, fast response time, high control accuracy and wide measurement range.
4 current ranges from 0.1μA ~ 150μA, 150μA ~ 5mA, 5mA ~ 150mA, 150mA ~ 5A can be selected respectively to realize the controllable accuracy of small current in small range.
● Discharge Data Protection
● Offline Testing Function
● Voltage Upper Limit Setting
● Voltage Lower Limit Setting
● Current Upper Limit Setting
● Current Lower Limit Setting
● Capacity Upper Limit Setting
● Voltage Fluctuation Protection
● Current Fluctuation Protection
Up to 1000Hz data recording frequency Compared to other modules of NEWARE testers, the CT-9000 series has a higher recording frequency up to 1000Hz. The IEC standard DCIR function of the CT-9000 is also based on the high frequency data set, allowing more DCIR values to be obtained in the same time range.
Integrated peripheral devices such as Auxiliary Voltage, Auxiliary Temperature, and Environmental TestChambers for comprehensive testing and evaluation, providing multi-dimensional and quantifiable support for battery mass production testing.
Support Differential Capacity Curve Test, designed for battery research in Universities, Research Institutes and etc.
The equipment has comprehensive functions, supports SMBus communication, and easily meets various needs.
● Voltage & Current Accuracy:±0.05% F.S.
● Sampling Time:100ms
● Number of Channels:16CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(15℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉≤50min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 59℉≤60min(25℃~15 ℃)
● Voltage & Current Accuracy:±0.01% F.S.
● Recording Frequency:100Hz
● Number of Channels:160CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(0℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉ ≤30min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 32℉≤50min(25℃~0 ℃)
● Voltage & Current Accuracy:±0.05% F.S.
● Recording Frequency:10Hz
● Number of Channels:160CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(0℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉ ≤30min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 32℉≤50min(25℃~0 ℃)
● Voltage & Current Accuracy:±0.05% F.S.
● Sampling Time:100ms
● Number of Channels:64CH
● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(15℃ ~ 60℃±2.0℃)
● Heating Efficiency:77℉ ~ 140℉≤50min(25℃ ~ 60℃)
● Cooling Efficiency:77℉ ~ 59℉≤60min(25℃~15 ℃)
● Temperature Range :32℉~140℉(0℃~60℃)
● Ambient Air Temperature :41℉~86℉(5℃~30℃)
● Temperature Fluctuation:≤1.8℉(1℃)(No load and stable temperature)
● Cooling Efficiency:≤40MINS(77℉→32℉)(25℃→0℃)
● Heating Efficiency:≤30MINS(77℉→140℉)(0℃→60℃)
● Temperature Deviation:±3.6℉(±2.0℃)(No load and stable temperature)