Unparalleled performance, tested to perfection.

Steady-state data acquisition.
Embracing the energy of precision.

±0.1% F.S.
Voltage & Current Accuracy
±0.1% F.S.
10Hz
Recording Frequency
10Hz
≤20ms
Current Response Time
≤20ms
500ms
Minimum Pulse Width
500ms
16Bit
Resolution Ratio
16Bit
100W
Max Output Power/Channel
100W

With stable performance parameters, it ensures accurate and reliable test data. It also adopts a modular design, with 8 channels per unit, allowing independent data acquisition for each channel. Each channel can be independently programmed, with a maximum editable row count of 254. Additionally, it features an energy feedback function, reducing production energy consumption and serving battery production companies, new energy vehicle manufacturers, and more.

All-around product tour.

Multiple testing modes.
One equipment, unlimited capabilities.

Cycle Life Test
Rate Charging / Discharging Test
Pulse Simulation Test
GITT Test
DCIR Test
dQ/dV Curve

Tailored for advanced battery testing: enabling dQ/dV differential capacity curve analysis capability.

dQ/dV differential capacity curve analysis graph

Compact in size, big on functionality.

With a height of 3U*, it occupies minimal space while offering numerous testing capabilities.  Multiple units can be assembled onto a gantry, allowing easy storage and fulfilling the requirements for testing multiple batteries.


 NEWARE Battery Testing Solutions
 NEWARE Battery Testing Solutions

Perpetual dedication to safety protection.

● Discharge Data Protection

● Offline Testing Function

● Voltage Upper Limit Setting

● Voltage Lower Limit Setting

● Current Upper Limit Setting

● Current Lower Limit Setting

● Capacity Upper Limit Setting

● Delay Time Setting

The product has various security protection features

Powerful programmability.
Meet diverse testing needs.

The software is fully functional, covering a variety of work-step settings, recording, and data storage to meet a wide range of testing needs.

DBC Configuration
CC & CV charge/discharge test
Segmented recording
DBC Configuration
CC & CV charge/discharge test
Segmented recording
Support import/edit/export of DBC files. Different battery pack protocols can be communicated by simply modifying the code of the DBC protocol file without upgrading the program.
CC charging or discharging until the voltage reaches the specified value, and then seamlessly switching to CV mode for battery compensation which is smooth without any spikes.
Allow to set up to 3 segment recording conditions per step, including voltage, current and time.

Extensive peripheral devices.
Create a multi-dimensional testing environment.

Integrated peripheral devices such as Auxiliary Voltage, Auxiliary Temperature, and Environmental TestChambers for comprehensive testing and evaluation, providing multi-dimensional and quantifiable support for battery mass production testing.

NEWARE battery tester-CT-4008-5V20A-A can connect to a variety of Integrated peripheral uses such as: Auxiliary Voltage, Auxiliary Temperature, and Environmental Test Chambers
NEWARE battery tester-CT-4008-5V20A- right tilt picture and front and back picture of a single control unit

Technical Specifications

Equipment name CT-4008-5V20A-A
Enter the power supply AC 220V ±10% / 50Hz
Input active power 1418 W
Resolution ratio AD: 16bit; DA: 16bit
Input impedence ≥1M Ω
Voltage
Constant voltage range control 0.025V~5V
Minimum discharge voltage 2.5V
Accuracy ± 0.1% of F.S.
Stability ± 0.1% of F.S.
Current
Output range per channel 0.1A~20A
Accuracy ± 0.1% of F.S.
Single-channel maximum output power 100 W
Stability ± 0.1% of F.S.
Time
Current rise time Maximum current rise time of 20ms (10% to 90% or 90% to 10%)
Working step time range (365 * 24) hour / step; time format supports 00:00:00.000 (h, min, s, ms)

Want to explore further?
Download our product technical specifications for more.

Download

CT-4008-5V20A-A

We offer powerful auxiliary equipments
and accessories to provide comprehensive testing support for battery testing.

We offer powerful auxiliary equipments and accessories to provide comprehensive testing support for battery testing.

· Instruments

NEWARE-Battery Tester-All-in-One Testing System-WIHW-200L-160CH-B

NEWARE-Environmental Test Chamber

WHW-200L-160CH-B

● Voltage & Current Accuracy:±0.01% F.S.

● Recording Frequency:100Hz

● Number of Channels:160CH

● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(0℃ ~ 60℃±2.0℃)

● Heating Efficiency:77℉ ~ 140℉ ≤30min(25℃ ~ 60℃)

● Cooling Efficiency:77℉ ~ 32℉≤50min(25℃~0 ℃)

NEWARE-Battery Tester-All-in-One Dual-Temperature Zones-WHW-100L-2-160CH

NEWARE-Environmental Test Chamber

WHW-100L-2-160CH

● Voltage & Current Accuracy:±0.05% F.S.

● Recording Frequency:10Hz

● Number of Channels:160CH

● Temperature Range & Deviation:32℉ ~ 140℉±3.6℉(0℃ ~ 60℃±2.0℃)

● Heating Efficiency:77℉ ~ 140℉ ≤30min(25℃ ~ 60℃)

● Cooling Efficiency:77℉ ~ 32℉≤50min(25℃~0 ℃)

NEWARE-Battery Tester-3C All-in-One Testing System-WGDW-380L-2-40BFC-5V600A8CH

NEWARE-Environmental Test Chamber

WHW-500L-5V6A80CH-380V

● Voltage & Current Accuracy:±0.05% F.S.

● Recording Frequency:100Hz

● Number of Channels:80CH

● Temperature Range & Deviation:50℉ ~ 185℉±3.6℉(10℃ ~ 85℃±2.0℃)

● Heating Efficiency:77℉ ~ 185℉ ≤40min(25℃ ~ 85℃)

● Cooling Efficiency:77℉ ~ 50℉≤40min(25℃~10 ℃)

NEWARE-Battery Tester-Constant Temperature Chamber-WHW-200L

NEWARE-Constant Temperature Chamber

WHW-200L

● Temperature Range :32℉~140℉(0℃~60℃)

● Ambient Air Temperature :41℉~86℉(5℃~30℃)

● Temperature Fluctuation:≤1.8℉(1℃)(No load and stable temperature)

● Cooling Efficiency:≤40MINS(77℉→32℉)(25℃→0℃)

● Heating Efficiency:≤30MINS(77℉→140℉)(0℃→60℃)

● Temperature Deviation:±3.6℉(±2.0℃)(No load and stable temperature)

· Auxilaries and Optional Accessories